Estimate only. R-value per inch varies by brand and density. Check the label and your local code for the R-value your area needs.
How to use this calculator
Enter the size of the area to insulate, such as an attic floor or a wall. Choose the target R-value and the type of insulation. Press Calculate to see the thickness you need and the total volume.
The formula
Thickness (in) = target R-value ÷ R-value per inch
Volume (cu ft) = area × thickness ÷ 12
Example: A 20 ft × 15 ft attic (300 sq ft) insulated to R-38 with blown cellulose (R-3.5 per inch) needs about 10.9 inches, or about 271 cubic feet.
Understanding your insulation estimate
The calculator gives two key numbers. Thickness tells you how deep the insulation must be to reach your target R-value. Volume tells you roughly how much material that takes. Together they help you compare products and plan how many bags or rolls to buy.
Why the insulation type matters
Each material resists heat differently per inch, so the same R-value needs very different depths. Take the 300 square foot attic from the example above. At R-38, blown cellulose needs about 10.9 inches. At R-49 with blown fiberglass, at about R-2.5 per inch, it needs about 19.6 inches. That is roughly 490 cubic feet of material. Make sure your attic has room for that depth without blocking vents.
Account for what you already have
Most attics already have some insulation. Measure its depth in a few spots and estimate its R-value with the same per-inch figures. For example, 4 inches of old cellulose gives about R-14. To reach R-38, you would add about R-24, which is about 6.9 inches of new cellulose. Enter the R-value you still need, not the full target, to get the added amount.
Tips before you start
- Seal air leaks first. Gaps around pipes, wires, light fixtures and the attic hatch can let warm air bypass the insulation.
- Keep soffit vents clear. Use baffles so insulation does not block airflow at the eaves.
- Keep insulation away from chimneys and recessed lights that are not rated for contact.
- Use depth markers stapled to joists so you can see when blown insulation is deep enough.
Common mistakes
- Compressing batts to fit a shallow space. Squashed insulation loses R-value.
- Covering wet or moldy insulation. Fix the roof or moisture problem first.
- Buying by volume alone. Blown insulation settles, and bags list coverage by R-value, not cubic feet.
- Leaving gaps around framing. Small voids lower the overall performance.
Buying and planning
Use the thickness from the calculator to check the coverage chart on the product you plan to buy. Bag charts show how many bags cover 1,000 square feet at each R-value. Compare a few types on price per square foot at your target R-value, not price per bag.
Wear a dust mask or respirator, goggles, gloves and long sleeves when you work with insulation. Check local building codes for the required R-value in your climate zone. Hire a pro for spray foam or if you find old wiring or vermiculite insulation.